Parts
Description | Remark | ST | |||||
---|---|---|---|---|---|---|---|
power mod. f. onboard pow. sup D >> - MJ 2009 |
'BCM1' | ||||||
1 | 8K0907063D | onboard supply control unit |
1 | ||||
2 | 1J0972977G | flat contact housing withcap slot: A |
32 pin grey |
1 | |||
3 | 1J0972977 | flat contact housing withcap slot: B |
32 pin black |
1 | |||
4 | 8E0972416 | flat contact housing withcontact locking mechanism slot: C |
16 pin brown |
1 | |||
5 | 4F0972483 | flat contact housing withcontact locking mechanism slot: D |
17-pin |
1 | |||
6 | 4F0972483A | flat contact housing withcontact locking mechanism slot: E |
17-pin |
1 | |||
7 | 4F0972483B | flat contact housing withcontact locking mechanism slot: F |
17-pin |
1 | |||
8 | 4F0937731 | flat contact housing withcontact locking mechanism slot: G |
6 pin |
1 | |||
10 | Переход к группе | bracket for vehicleselectrical system control unit see illustration, item: 971-080,15 |
|||||
power mod. f. onboard pow. sup D >> - MJ 2009 |
'BCM2' | ||||||
15 | 8K0907064CT | central control unit forconvenience system see parts bulletin: (9-101) |
433MHZ |
1 | PR-5D1 | ||
15 | f | (8K0907064AT) | central control unit forconvenience system see parts bulletin: (9-90) |
433MHZ,434MHZ ; no longer available |
1 | PR-5D1 | |
(15) | f | 8K0907064R | central control unit forconvenience system see parts bulletin: (9-101) |
315MHZ |
1 | PR-5D2,5D3, 5D4 |
|
(15) | 8K0907064CS | central control unit forconvenience system see parts bulletin: (9-101) |
315MHZ |
1 | PR-5D2,5D3, 5D4 |
||
(15) | f | (8K0907064AS) | central control unit forconvenience system see parts bulletin: (9-90) |
315MHZ ; no longer available |
1 | PR-5D2,5D3, 5D4 |
|
(15) | 8K0907064CQ | central control unit forconvenience system see parts bulletin: (9-101) |
868MHZ |
1 | PR-5D7 | ||
(15) | f | (8K0907064P) | central control unit forconvenience system see parts bulletin: (9-101) |
868MHZ ; no longer available |
1 | PR-5D7 | |
(15) | 8K0907064CQ | central control unit forconvenience system see parts bulletin: (9-101) |
868MHZ |
1 | PR-5D7 | ||
(15) | f | (8K0907064AQ) | central control unit forconvenience system see parts bulletin: (9-90) |
868MHZ ; no longer available |
1 | PR-5D7 | |
16 | 4F0972483 | flat contact housing withcontact locking mechanism slot: A |
17-pin black |
1 | |||
17 | 1J0972977 | flat contact housing withcap slot: B |
32 pin black |
1 | |||
18 | 4F0972483A | flat contact housing withcontact locking mechanism slot: C |
17-pin brown |
1 | |||
19 | 4E0035610K | removable housing for aerialbracket female connector cable output: lower slot: D |
1 point |
1 | |||
20 | 1J0972977G | flat contact housing withcap slot: E |
32 pin grey |
1 | |||
21 | 8E0906236 | flat contact housing slot: G |
6 pin black |
1 | |||
22 | 1J0972977D | flat contact housing withcap slot: F |
32 pin blue |
1 | |||
(23) | 8R0907461A | retainer for power module |
1 | ||||
24 | N 01508210 | hexagon collar nut |
M6 | 2 | |||
24 | (N 01508213) | hexagon collar nut |
M6; no longer available |
2 | |||
diagnosis interface for
data bus (gateway) D >> - MJ 2009 |
'CAN' | PR-8UD,8UL, 8UM,8YN |
|||||
30 | (8T0907468H) | diagnosis interface fordata bus (gateway) |
CAN; no longer available |
1 | PR-7Y0+8N1, 8N6+8T0,8T1 |
||
30 | 8T0907468M | diagnosis interface fordata bus (gateway) see parts bulletin: (9-98) |
CAN |
1 | PR-7Y0+8N1, 8N6+8T0,8T1 |
||
(30) | (8T0907468J) | diagnosis interface fordata bus (gateway) |
CAN; no longer available |
1 | PR-7Y0+8N7+ 8T0,8T1 |
||
(30) | 8T0907468N | diagnosis interface fordata bus (gateway) see parts bulletin: (9-98) |
CAN |
1 | PR-7Y0+8N7+ 8T0,8T1 |
||
(30) | (8T0907468J) | diagnosis interface fordata bus (gateway) |
CAN; no longer available |
1 | PR-7Y1,7Y2, 7Y3 |
||
(30) | 8T0907468N | diagnosis interface fordata bus (gateway) see parts bulletin: (9-98) |
CAN |
1 | PR-7Y1,7Y2, 7Y3 |
||
(30) | (8T0907468J) | diagnosis interface fordata bus (gateway) |
CAN; no longer available |
1 | PR-7Y0+8T4 | ||
(30) | 8T0907468N | diagnosis interface fordata bus (gateway) see parts bulletin: (9-98) |
CAN |
1 | PR-7Y0+8T4 | ||
diagnosis interface for
data bus (gateway) D >> - MJ 2009 |
'MOST' | PR-8DP,8DY, 8DZ,8UV,8YQ, 8AJ,8YF |
|||||
(30) | (8T0907468K) | diagnosis interface fordata bus (gateway) |
MOST; no longer available |
1 | PR-7Y0+8N1+ 8N6+8T0,8T1 |
||
(30) | 8T0907468P | diagnosis interface fordata bus (gateway) see parts bulletin: (9-98) |
MOST |
1 | PR-7Y0+8N1+ 8N6+8T0,8T1 |
||
(30) | (8T0907468L) | diagnosis interface fordata bus (gateway) |
MOST; no longer available |
1 | PR-7Y0+8T4 | ||
(30) | 8T0907468Q | diagnosis interface fordata bus (gateway) see parts bulletin: (9-98) |
MOST |
1 | PR-7Y0+8T4 | ||
(30) | (8T0907468L) | diagnosis interface fordata bus (gateway) |
MOST; no longer available |
1 | PR-7Y0+8N7+ 8T0,8T1 |
||
(30) | 8T0907468Q | diagnosis interface fordata bus (gateway) see parts bulletin: (9-98) |
MOST |
1 | PR-7Y0+8N7+ 8T0,8T1 |
||
(30) | (8T0907468L) | diagnosis interface fordata bus (gateway) |
MOST; no longer available |
1 | PR-7Y1,7Y2, 7Y3 |
||
(30) | 8T0907468Q | diagnosis interface fordata bus (gateway) see parts bulletin: (9-98) |
MOST |
1 | PR-7Y1,7Y2, 7Y3 |
||
31 | 8E0972420 | flat contact housing withcontact locking mechanism also to be used for: blue cable output: side 45 |
20 pin red |
1 | |||
(31) | 8E0972420B | flat contact housing withcontact locking mechanism cable output: upper |
20 pin red |
1 | |||
(31) | 8E0972420C | flat contact housing withcontact locking mechanism cable output: side |
20 pin black |
1 | |||
32 | 4E0973702 | flat connector fibre optic wave conductor |
2 pin black |
1 | |||
33 | N 10549503 | hexagon head bolt (combi) |
M5X16 | 2 |