Parts
Description | Remark | ST | |||||
---|---|---|---|---|---|---|---|
air distribution housing evaporator housing evaporator fan footwell vent |
air condit. |
||||||
1 | 8E0260749 | o-ring for refrigerant: R134A |
10,8X1,82 |
1 | |||
1 | (8A0260749AJ) | o-ring for refrigerant: R134A |
10,80X1,82 ; no longer available |
1 | |||
(1) | c | 803260749A | o-ring for refrigerant: R 12 |
10X1,7 |
2 | ||
2 | 8E0260749D | o-ring for refrigerant: R134A |
14X1,8 |
1 | |||
2 | (8A0260749AH) | o-ring for refrigerant: R134A |
14X17,65 ; no longer available |
1 | |||
(1) | c | 803260749B | o-ring for refrigerant: R12 |
13X1,7 |
2 | ||
3 | 1H0819056 | double stud with hexagon drive |
1 | ||||
4 | 321819059 | clip |
X | ||||
6 | c | 1H1819081 | intermediate piece |
lhd |
1 | ||
(6) | 1H2819081 | intermediate piece |
rhd |
1 | |||
7 | 1H0819090B | seal |
1 | ||||
(8) | 1H1819098A | intake manifold |
lhd |
1 | |||
(8) | 1H2819098A | intake manifold |
rhd |
1 | |||
9 | c | 1H1819151 | footwell vent |
lhd |
1 | ||
(9) | 1H2819151 | footwell vent |
rhd |
1 | |||
10 | 1H0819165 | seal |
1 | ||||
10A | 1H0819166 | seal |
1 | ||||
11 | 191819370 | seal |
1 | ||||
14 | (1H1819631) | dust and pollen filter |
lhd ; no longer available |
1 | |||
(14) | (1H2819631) | dust and pollen filter |
rhd ; no longer available |
1 | |||
15A | 1H0819644B | dust and pollen filter insert also use: >>1H-P-990000 1H0 819 648 A 1J1 819 640 B 1J2 819 640 A |
1 1 1 1 |
lhd rhd |
|||
15A | JZW819653 | filter insert with odour andharmful substance filter eco economy also use: 1H0 819 648 A 1J1 819 640 B 1J2 819 640 A |
>>1H-P-990000 |
1 1 1 1 |
lhd rhd |
||
15A | (1H0819644) | dust and pollen filter insert also use: >>1H-P-990000 1H0 819 648A 1H1 819 640 A 1H2 819 640 A |
; no longer available |
1 1 1 1 |
lhd rhd |
||
15B | (1H0819648) | frame filter element F 1H-R-000 001>> |
no longer available | 1 1 |
|||
16 | (1H1819640) | filter housing for vehicles with dust andpollen filter F >> 1H-P-990 000 |
lhd lhd ; no longer available |
1 1 |
|||
15B | 1H0819648A | frame filter element F 1H-R-000 001>> |
1 1 |
||||
16 | 1J1819640B | filter housing for vehicles with dust andpollen filter F >> 1H-P-990 000 |
lhd lhd |
1 1 |
|||
16 | (1H1819640A) | filter housing for vehicles with dust andpollen filter F >> 1H-P-990 000 |
lhd lhd ; no longer available |
1 1 |
|||
(16) | (1H2819640) | filter housing for vehicles with dust andpollen filter F >> 1H-P-990 000 |
rhd ; no longer available |
1 |
|||
(16) | 1J1819640B | filter housing for vehicles with dust andpollen filter F 1H-R-000 001>> |
lhd lhd |
1 1 |
|||
(16) | (1H1819640A) | filter housing for vehicles with dust andpollen filter F 1H-R-000 001>> |
lhd lhd ; no longer available |
1 1 |
|||
(16) | 1J2819640A | filter housing for vehicles with dust andpollen filter F >> 1H-P-990 000 |
rhd rhd |
1 |
|||
(16) | (1H2819640A) | filter housing for vehicles with dust andpollen filter F >> 1H-P-990 000 |
rhd rhd ; no longer available |
1 |
|||
(16) | 1J2819640A | filter housing for vehicles with dust andpollen filter F 1H-R-000 001>> |
rhd |
1 |
|||
(16) | (1H2819640A) | filter housing for vehicles with dust andpollen filter F 1H-R-000 001>> |
rhd ; no longer available |
1 |
|||
17 | 1H0819943 | round hd. screw |
3 | ||||
18 | 1H1820021 | fan |
lhd |
1 | |||
(18) | 1H2820021 | fan |
rhd |
1 | |||
19 | c | 1H1820024 | housing |
lhd |
1 | ||
(19) | c | 1H2820024 | housing |
rhd |
1 | ||
21 | 191820048 | ring |
1 | ||||
22 | 321820061D | seal shorten to: 95MM |
1220X12X10 |
1 | |||
23 | 1H1820103 | evaporator with expansionvalve for refrigerant: R12 F >> 1H-N-990 000 |
lhd |
1 |
|||
(23) | (1H1820103B) | evaporator with expansionvalve for refrigerant: R134A F 1H-P-000 001>> |
lhd lhd ; no longer available |
1 1 |
|||
(23) | 1H1820103C | evaporator with expansionvalve for refrigerant: R134A F 1H-P-000 001>> |
lhd lhd |
1 1 |
|||
(23) | c | 1H2820103 | evaporator with expansionvalve for refrigerant: R12 F >> 1H-N-990 000 |
rhd |
1 |
||
(23) | (1H2820103B) | evaporator with expansionvalve for refrigerant: R134A F 1H-P-000 001>> |
rhd ; no longer available |
1 |
|||
(23) | 1H2820103C | evaporator with expansionvalve for refrigerant: R134A F 1H-P-000 001>> |
rhd rhd |
1 |
|||
24 | 1H0820119 | water drain valve |
1 | ||||
25 | 191820129 | seal |
2 | ||||
26 | 1H0820133 | seal |
2 | ||||
27 | 1H1820139 | seal |
lhd |
1 | |||
(27) | c | 1H2820139 | seal |
rhd |
1 | ||
29 | 1H1820149 | rubber bush |
lhd |
1 | |||
(29) | 1H2820149 | rubber bush |
rhd |
1 | |||
31 | 1H1820281 | reinforcement plate |
lhd |
1 | |||
(31) | c | 1H2820281 | reinforcement plate |
rhd |
1 | ||
32 | (1H1820295) | thermostat with protective cap |
lhd ; no longer available |
1 | |||
(32) | (1H2820295) | thermostat with protective cap |
rhd ; no longer available |
1 | |||
32 | 357820295B | thermostat with protective cap |
lhd |
1 | |||
32 | (357820295) | thermostat with protective cap |
lhd ; no longer available |
1 | |||
(32) | 358820295B | thermostat with protective cap |
rhd |
1 | |||
(32) | (358820295) | thermostat with protective cap |
rhd ; no longer available |
1 | |||
33 | 1H1820351 | connection box |
lhd |
1 | |||
(33) | 1H2819351 | air distribution housing |
rhd |
1 | |||
34 | 1H1820593A | cover |
lower lhd |
1 | |||
(34) | 1H2820593 | cover |
lower rhd |
1 | |||
35 | 1H1820677 | vacuum unit air distribution housing intake duct |
lhd |
1 | |||
(35) | c | 1H2820677 | vacuum unit |
rhd |
1 | ||
36 | c | 1H0820679 | expansion valve for refrigerant: R12 F >> 1H-N-990 000 |
1 |
|||
(36) | (1H0820679A) | expansion valve for refrigerant: R134A F 1H-P-000 001>> |
; no longer available |
1 1 |
|||
(36) | 6N0820679C | expansion valve F 1H-P-000 001>> |
R134A | 1 1 |
|||
(36) | (6N0820679A) | expansion valve F 1H-P-000 001>> |
R134A; no longer available |
1 1 |
|||
37 | 1H0820692 | insulating piece |
1 | ||||
1H0820692 01C | insulating piece satin black |
01.92 - 07.94 |
|||||
38 | 1H0816831 | flange expansion valve |
1 | ||||
39 | 191820845 | tensioning strap |
1 | ||||
40 | N 0106551 | socket head bolt |
M5X55 | 2 | |||
43 | 701959263A | series resistance for freshair and hot air blower |
1,9/0,92/0,26 | 1 | |||
44 | N 0139655 | oval head panel screw |
4,2X9,5 | X | |||
46 | N 0139694 | oval head panel screw |
ST4,8X16,0 | 4 | |||
47 | N 0140993 | oval hd. csk. self-tapp. screw |
4,8X13 | X | |||
48 | N 0154421 | speed nut |
4,2X12,8X11,5 | 1 | |||
50 | (N 90081801) | oval head panel screw (combi) |
B4,8X16Z2; no longer available |
3 | |||
50 | N 10309101 | oval head panel screw (combi) |
4,8X16 | 3 | |||
51 | N 90216201 | hex. nut |
M6 | 4 | |||
52 | N 90276701 | speed nut |
4,8X14,25 | 4 | |||
53 | N 90352101 | hexagon collar nut |
5 | 1 | |||
(54) | (N 90205501) | cable ties |
4,5X140; no longer available |
1 | |||
(54) | N 90666101 | cable ties |
4,6X200 | 1 | |||
55 | 1H1898001 | 1 set: levers for airdistribution housing |
lhd |
1 | |||
(55) | 1H2898001 | 1 set: levers for airdistribution housing |
rhd |
1 |